The PO-AC-6G-80 is a 6.6 kW on-board charger for 80 V-class electric vehicles. It takes either an AC grid supply (90–265 Vac) or a 400 Vdc source and charges the traction battery at 0–105 Vdc / 0–80 A, with maximum efficiency of ≥92%.
Integrating both input paths in one unit means the vehicle charges from mains where a socket exists and from a DC bus where it does not, without an extra off-board converter at the point of use.
The control side is built on AUTOSAR with CAN 2.0, UDS diagnostics, BootLoader and UDS firmware refresh, and follows GB/T 20234 charging signal requirements. Air or liquid cooling is available on the same model, and the unit weighs under 6.5 kg.
PO-AC-6G-80
Echelon
| Availability: | |
|---|---|
| Quantity: | |
What it is: a 6.6 kW on-board charger for 80 V-class electric vehicles that accepts either an AC grid supply (90–265 Vac) or a 400 Vdc source through the same unit, model PO-AC-6G-80.
Best for: vehicles that have to charge wherever they are parked — from a wall socket in the depot, or from a DC bus where no AC supply exists.
Key specs: 6600 W output, 0–105 Vdc, 0–80 A, ≥92% efficiency, CAN 2.0 with UDS diagnostics and BootLoader, AUTOSAR software, air or liquid cooling, under 6.5 kg.
The PO-AC-6G-80 puts an AC charging stage and a DC charging stage into one 80 V-class on-board charger. A conventional OBC only knows how to take AC from the grid; on machines that spend their working life far from a socket — in a materials yard, on a farm, at a remote site — that leaves the vehicle dependent on someone running a cable to it.
Adding a DC input path means the same charger can take power from a 400 Vdc source when one is available, and from ordinary mains when it is not. The vehicle keeps one charging connector, one charger and one integration procedure; what changes is where the energy can come from.
The control side is built on AUTOSAR, with CAN 2.0 communication, UDS diagnostics, BootLoader and UDS firmware refresh, and it follows the GB/T 20234 charging signal requirements. For a vehicle programme that has to hand software integration to a third-party ECU supplier, that is usually the difference between a two-week integration and a two-month one.
It is worth being precise, because “AC/DC dual input” gets used loosely. On this unit the AC path takes 90–265 Vac from the grid; the DC path takes a 400 Vdc source. Both feed the same internal charging stage and the same 0–105 Vdc output to the traction battery.
Three situations where that matters:
Situation | What changes for the vehicle |
Depot with only AC available | Charges from 90–265 Vac mains at the full 6.6 kW, the same as a single-input OBC — no penalty for carrying the DC path. |
Site with a 400 Vdc bus | Charges directly from the DC source, so no separate off-board AC/DC supply and no extra cabinet is needed at the point of use. |
Mixed fleet, one charger type | One charger model spans both charging styles, which simplifies spare stock and service training across a mixed fleet. |
If your programme will only ever see AC mains, a single-input OBC is the cheaper answer and we will say so. The DC path earns its place when the vehicle's charging location is not guaranteed to have a grid connection.
6600 W rated, 0–105 Vdc output, 0–80 A, with maximum efficiency of ≥92%. On an 80 V nominal pack that current headroom matters: 80 A lets the charger hold full power well into the constant-current phase instead of tapering early.
90–265 Vac on the grid side, 400 Vdc on the DC side, both routed through the same charging stage and the same output.
CAN 2.0 communication, UDS diagnostics, BootLoader and UDS program refresh, developed on the AUTOSAR architecture so integration follows a standardised vehicle software model rather than a proprietary protocol.
Both thermal options are available on the same model, so the choice can follow the mounting position rather than the other way round: air where the enclosure has an airflow path, liquid where it does not.
Integrated protection covers both input and output sides:
Input over-voltage and under-voltage
Output over-voltage and under-voltage
Reverse connection
Output short circuit
Over-temperature, with automatic power derating and recovery
Operating range −40 °C to +85 °C, storage to +95 °C, industrial vibration resistance, salt spray resistance and EMC compliance to GB/T 18487.3. Unit weight is under 6.5 kg.
Item | Specification |
Model | PO-AC-6G-80 |
Battery platform | 80 V DC |
Charging power | 6.6 kW (6600 W) |
AC input voltage | 90–265 Vac |
DC input voltage | 400 Vdc |
Output voltage | 0–105 Vdc |
Output current | 0–80 A |
Maximum efficiency | ≥92% |
Communication | CAN 2.0 |
Software support | UDS diagnostics, BootLoader, UDS program refresh |
Development platform | AUTOSAR |
Cooling method | Air cooling / liquid cooling |
Weight | <6.5 kg |
Operating temperature | −40 °C to +85 °C |
Storage temperature | −40 °C to +95 °C |
Charging signal standard | GB/T 20234 |
EMC standard | GB/T 18487.3 |
The rated temperature range reaches +85 °C, but full power does not follow it all the way. When the heatsink exceeds 75 °C the charger deliberately reduces output, then restores it automatically once the temperature falls back below the recovery threshold.
That behaviour is normal and desirable — it protects the power stage instead of tripping off — but it changes what you can promise an operator. If a vehicle has to leave the depot fully charged within a fixed window on a hot day, size the charge window against derated power rather than against 6.6 kW, or specify liquid cooling to hold the heatsink below the threshold. Send us the ambient temperature at the mounting position and the duty cycle, and we will tell you which of the two applies.
The dual input suits vehicles that work away from a fixed charging point:
Electric utility and works vehicles
Electric cargo vehicles and logistics vehicles
Electric tractors and agricultural machinery
Electric sweepers and sanitation vehicles
Airport ground support equipment (GSE)
Low-speed commercial EVs and specialty vehicles
Four things decide whether this charger fits a specific programme:
Pack voltage window — nominal and maximum, to confirm the 0–105 Vdc output spans it with margin.
Pack capacity in kWh or Ah, which sets the charge time you need.
Charging source — AC only, 400 Vdc only, or both, and what the site can actually supply.
Mounting position and ambient, which decides air versus liquid cooling.
With those four we can confirm the model, state the charge time it delivers and flag if the thermal path will force derating.
No. It accepts either an AC supply or a DC supply and routes the selected source through the same charging stage. The value is that the vehicle can charge from whichever source is present at the site, not that the two are combined.
It lets the vehicle charge from a 400 Vdc source directly, without an off-board AC/DC converter at the point of use. That matters on sites that already have a DC bus — industrial yards, farms and remote installations — where running mains to the parking spot is expensive or impossible.
Not always, but it depends on the installation. The unit derates above a 75 °C heatsink, so air cooling holds full power only while the enclosure can move enough air. In a sealed compartment or a hot climate, liquid cooling is the safer specification.
It means the charger's software follows a standardised architecture with CAN 2.0, UDS diagnostics and BootLoader, so it can be flashed in the field and integrated with third-party VCU and BMS software without a bespoke protocol layer.
The 0–105 Vdc output window will cover a 72 V or 96 V pack electrically, but this model is specified against an 80 V-class platform. Tell us the actual pack window and we will confirm the right model rather than assume this one — we build the 2-in-1 range across 48 V, 72 V, 96 V and 320 V platforms as well.
Send the four items above and we will confirm whether the PO-AC-6G-80 fits, or point you to the model that does. Contact us or email nancy@tici-energy.com. For programmes that also need low-voltage auxiliary power from the same housing, see the AC/DC dual-input 2-in-1 range.
content is empty!