All six are air-cooled and share the same integration approach. Scroll down for the sizing guide, IP67/CAN matrix and FAQ.
Quick answer: an OBC + DC/DC 2-in-1 is one housing that does two jobs — it converts AC mains into DC to charge the traction battery, and it steps that high-voltage pack voltage down to 12–16 V DC for lights, controllers and auxiliary loads. Echelon builds these modules for 48 V, 72 V, 96 V and 320 V platforms, covering 1.5–6.6 kW charging and 500 W–1.5 kW auxiliary output across six series.
On a conventional low-volume EV build, charging and auxiliary power arrive as two separate boxes: a charger bolted to one bracket, a DC/DC converter on another, each with its own high-voltage inlet, its own CAN node, its own low-voltage outlet and its own thermal path. Combining them removes one housing, one mounting bracket set, one high-voltage harness run and one low-voltage distribution point.
What changes in practice:
One high-voltage interface instead of two — fewer contactor and fuse positions to account for.
One thermal design — the charger and converter share the same air path and the same over-temperature strategy.
One EMC and environmental test scope for the power stage rather than two.
One part number to stock and one unit to trace through service.
The trade-off is that a fault in either function takes the module offline, so the protection set has to cover both halves. All series are specified with over-voltage, under-voltage, over-current, short-circuit and over-temperature protection.

The charging side and the auxiliary side are listed separately, because they are sized by different constraints — charging by pack energy and the AC supply, auxiliary output by the vehicle's worst-case low-voltage load.
Charging side
| Model | Platform | OBC power | OBC output |
| OD-CA-1F0G-48Y | 48 V | 1500 W | 37–58 V, 0–30 A |
| OD-CH-1F0F-72Y | 72 V | 1500 W | 40–96 V, 0–20 A |
| OD-CA-2A1A-72 / -96 / -320 | 72 / 96 / 320 V | 2000 W | 50–100 / 64–128 / 240–480 V 0–28 / 0–20 / 0–6.5 A |
| OD-CE-3D1A-72 / -96 / -320 | 72 / 96 / 320 V | 3300 W | 50–105 / 64–128 / 240–480 V 0–40 / 0–32 / 0–10 A |
| OD-CC-3D1F-96Y / -320Y | 96 / 320 V | 3300 W | 64–128 / 240–480 V 0–34 / 0–12 A |
| OD-CD-6G1F-72 / -96 / -320 | 72 / 96 / 320 V | 6600 W @ 220 Vac 3300 W @ 110 Vac | 50–100 / 64–128 / 240–480 V 0–80 / 0–60 / 0–20 A |
Auxiliary side
| Model | DC/DC power | DC/DC output | Cooling | Weight |
| OD-CA-1F0G-48Y | 600 W | 9–16 V, 40 A | Air | ≤4.5 kg |
| OD-CH-1F0F-72Y | 500 W | 9–16 V 36 A rated / 43 A peak | Forced air | — |
| OD-CA-2A1A-72 / -96 / -320 | 1000 W | 14 V ±0.2 V 72 A rated / 86 A peak | Air | ≤4.5 kg |
| OD-CE-3D1A-72 / -96 / -320 | 1000 W 1200 W peak | 14 V ±0.2 V | Air | ≤6 kg |
| OD-CC-3D1F-96Y / -320Y | 1500 W 1800 W peak | 9–16 V | Air | — |
| OD-CD-6G1F-72 / -96 / -320 | 1500 W | 14 V ±0.2 V, 110 A | Air | — |
Two details in those tables matter more than they look. First, the 6.6 kW series delivers 6600 W only on a 220–240 Vac supply; on 110 Vac it is a 3300 W charger. Second, the DC/DC peak figures are short-term — 86 A on the 2 kW series and 1.8 kW on the 3.3 kW + 1.5 kW series are for transient loads such as compressor start-up, not for continuous draw.
Take your pack's nominal and maximum voltage, then confirm the charger's output window spans it with margin at both ends. A 72 V nominal pack on the 72 V series sits inside a 40–105 V window on the OD-CE-3D1A-72, which leaves room for a fully charged pack and for low-temperature sag.
Divide pack energy by charger power to get the theoretical minimum charge time. A 72 V, 100 Ah pack holds 7.2 kWh:
2 kW charger — about 3.6 h theoretically
3.3 kW charger — about 2.2 h
6.6 kW charger on 220 Vac — about 1.1 h
Treat those as a floor, not a promise: real charge time is longer because current tapers in the constant-voltage phase, because the AC supply may not hold full power, and because a BMS may cap input current. Size one step above the minimum you can tolerate, and check whether the site actually has 220 Vac available before specifying the 6.6 kW version.
Add up continuous low-voltage draw at worst case — headlights and work lights, wipers, cabin fan, controller and BMS supply, plus any DC/AC inverter for tools or refrigeration. Then keep the continuous total under the rated figure (for example 14 V × 72 A ≈ 1 kW on the 2 kW series) and let peaks land inside the peak rating. If an inverter or a compressor dominates the budget, size against that load rather than against the average.
Not every series is documented identically, so this is worth checking before you put a part number in a drawing pack:
IP67 is specified on the OD-CH-1F0F-72Y and on the OD-CE-3D1A series. For OD-CA and OD-CD, ask for the ingress rating in writing for your mounting position.
CAN bus is specified on the OD-CA-2A1A series and on the OD-CC-3D1F series. The OD-CA-1F0G-48Y and OD-CH-1F0F-72Y are documented with a 12 V enable signal path rather than CAN — confirm the control interface you need at RFQ.
Efficiency is quoted per series, not per model: ≥94% on OD-CA-2A1A and OD-CC-3D1F, ≥91% on OD-CH-1F0F-72Y and OD-CE-3D1A, with the OD-CD-6G1F split as ≥93% OBC and ≥94% DC/DC.
All six series in this range are air-cooled. If your enclosure cannot move enough air, the honest answer is a different thermal design rather than a bigger fan — tell us the ambient and the duty cycle and we will say so.
Two cases where splitting the functions is better:
You need high-voltage distribution as well. If the vehicle also needs contactors, fusing and pre-charge for a high-voltage bus, the OBC + DC/DC + PDU 3-in-1 range folds distribution into the same housing instead of adding a third box.
Charging and auxiliary power have very different duty cycles. On a machine that charges overnight but runs its auxiliary load all day, a dedicated converter may be easier to service than a shared housing. We build standalone OBCs and DC/DC converters for exactly that case.
Not defined by vehicle type. Three conditions decide it:
48–320 V pack — the charger's output window must span your pack from empty to full
A 12–16 V auxiliary bus — lights, controllers, BMS, fans
One bay, not two — if there is room for separate units, buying separately is often cheaper
Body shape, duty cycle and market change the connector and the CAN map, not whether the architecture works.
Common programmes






Also in series: RVs and campers · Golf carts and LSVs · Forklifts and AGVs · Airport ground support · Sanitation · Agricultural tractors · Autonomous delivery — and vehicles not listed here.
Send the five numbers and we will say whether one of the six series fits, or whether the programme needs a separate unit.
A 2-in-1 combines an on-board charger and a DC/DC converter. A 3-in-1 adds a power distribution unit, so high-voltage fusing, contactor control and pre-charge live in the same housing as well. Choose 2-in-1 when the vehicle already has a distribution box; choose 3-in-1 when the housing count is the constraint.
Yes — that is the main reason to integrate the two functions. Both operate from the same high-voltage bus, so auxiliary systems keep running during a charge session, which matters for vehicles that must stay powered on the charger: refrigerated vans, work platforms and machines with an active telematics unit.
Not automatically. The 6.6 kW series in this range is air-cooled, and air is usually sufficient when the module has its own airflow path and the ambient stays within the specified range. Liquid cooling becomes the better choice when the module sits in a sealed compartment or when ambient is high and the duty cycle is continuous.
It means 3300 W. The 6.6 kW figure applies to a 220–240 Vac input; on 110 Vac the same module delivers half the power. If your target market is 110 V only, size the vehicle's charge time from 3.3 kW.
Send four things: nominal and maximum pack voltage, pack capacity in kWh or Ah, the continuous auxiliary load in watts, and the ambient temperature at the mounting position. With those we can name a model, state the charge time it delivers and flag whether the thermal path is realistic — usually within one working day.
Tell us the platform voltage and the auxiliary budget and we will shortlist the model that fits, or say plainly if none of the six does. Send your requirement or email nancy@tici-energy.com.