OBC+DC/DC 2-in-1

Quick answer: an OBC + DC/DC 2-in-1 is one housing that does two jobs — it converts AC mains into DC to charge the traction battery, and it steps that high-voltage pack voltage down to 12–16 V DC for lights, controllers and auxiliary loads. Echelon builds these modules for 48 V, 72 V, 96 V and 320 V platforms, covering 1.5–6.6 kW charging and 500 W–1.5 kW auxiliary output across six series.

What an OBC + DC/DC 2-in-1 module actually replaces

On a conventional low-volume EV build, charging and auxiliary power arrive as two separate boxes: a charger bolted to one bracket, a DC/DC converter on another, each with its own high-voltage inlet, its own CAN node, its own low-voltage outlet and its own thermal path. Combining them removes one housing, one mounting bracket set, one high-voltage harness run and one low-voltage distribution point.

What changes in practice:

  • One high-voltage interface instead of two — fewer contactor and fuse positions to account for.

  • One thermal design — the charger and converter share the same air path and the same over-temperature strategy.

  • One EMC and environmental test scope for the power stage rather than two.

  • One part number to stock and one unit to trace through service.

The trade-off is that a fault in either function takes the module offline, so the protection set has to cover both halves. All series are specified with over-voltage, under-voltage, over-current, short-circuit and over-temperature protection.

OBC and DC-DC 2-in-1 modules


The range at a glance

The charging side and the auxiliary side are listed separately, because they are sized by different constraints — charging by pack energy and the AC supply, auxiliary output by the vehicle's worst-case low-voltage load.

Charging side

ModelPlatformOBC powerOBC output
OD-CA-1F0G-48Y48 V1500 W37–58 V, 0–30 A
OD-CH-1F0F-72Y72 V1500 W40–96 V, 0–20 A
OD-CA-2A1A-72 / -96 / -32072 / 96 / 320 V2000 W50–100 / 64–128 / 240–480 V
0–28 / 0–20 / 0–6.5 A
OD-CE-3D1A-72 / -96 / -32072 / 96 / 320 V3300 W50–105 / 64–128 / 240–480 V
0–40 / 0–32 / 0–10 A
OD-CC-3D1F-96Y / -320Y96 / 320 V3300 W64–128 / 240–480 V
0–34 / 0–12 A
OD-CD-6G1F-72 / -96 / -32072 / 96 / 320 V6600 W @ 220 Vac
3300 W @ 110 Vac
50–100 / 64–128 / 240–480 V
0–80 / 0–60 / 0–20 A

Auxiliary side

ModelDC/DC powerDC/DC outputCoolingWeight
OD-CA-1F0G-48Y600 W9–16 V, 40 AAir≤4.5 kg
OD-CH-1F0F-72Y500 W9–16 V
36 A rated / 43 A peak
Forced air—
OD-CA-2A1A-72 / -96 / -3201000 W14 V ±0.2 V
72 A rated / 86 A peak
Air≤4.5 kg
OD-CE-3D1A-72 / -96 / -3201000 W
1200 W peak
14 V ±0.2 VAir≤6 kg
OD-CC-3D1F-96Y / -320Y1500 W
1800 W peak
9–16 VAir—
OD-CD-6G1F-72 / -96 / -3201500 W14 V ±0.2 V, 110 AAir—

Two details in those tables matter more than they look. First, the 6.6 kW series delivers 6600 W only on a 220–240 Vac supply; on 110 Vac it is a 3300 W charger. Second, the DC/DC peak figures are short-term — 86 A on the 2 kW series and 1.8 kW on the 3.3 kW + 1.5 kW series are for transient loads such as compressor start-up, not for continuous draw.

How to size the module in three steps

Step 1 — fix the platform window

Take your pack's nominal and maximum voltage, then confirm the charger's output window spans it with margin at both ends. A 72 V nominal pack on the 72 V series sits inside a 40–105 V window on the OD-CE-3D1A-72, which leaves room for a fully charged pack and for low-temperature sag.

Step 2 — choose OBC power from pack energy and charge window

Divide pack energy by charger power to get the theoretical minimum charge time. A 72 V, 100 Ah pack holds 7.2 kWh:

  • 2 kW charger — about 3.6 h theoretically

  • 3.3 kW charger — about 2.2 h

  • 6.6 kW charger on 220 Vac — about 1.1 h

Treat those as a floor, not a promise: real charge time is longer because current tapers in the constant-voltage phase, because the AC supply may not hold full power, and because a BMS may cap input current. Size one step above the minimum you can tolerate, and check whether the site actually has 220 Vac available before specifying the 6.6 kW version.

Step 3 — choose DC/DC power from the auxiliary budget

Add up continuous low-voltage draw at worst case — headlights and work lights, wipers, cabin fan, controller and BMS supply, plus any DC/AC inverter for tools or refrigeration. Then keep the continuous total under the rated figure (for example 14 V × 72 A ≈ 1 kW on the 2 kW series) and let peaks land inside the peak rating. If an inverter or a compressor dominates the budget, size against that load rather than against the average.

Which models carry IP67 and CAN, and which need confirming

Not every series is documented identically, so this is worth checking before you put a part number in a drawing pack:

  • IP67 is specified on the OD-CH-1F0F-72Y and on the OD-CE-3D1A series. For OD-CA and OD-CD, ask for the ingress rating in writing for your mounting position.

  • CAN bus is specified on the OD-CA-2A1A series and on the OD-CC-3D1F series. The OD-CA-1F0G-48Y and OD-CH-1F0F-72Y are documented with a 12 V enable signal path rather than CAN — confirm the control interface you need at RFQ.

  • Efficiency is quoted per series, not per model: ≥94% on OD-CA-2A1A and OD-CC-3D1F, ≥91% on OD-CH-1F0F-72Y and OD-CE-3D1A, with the OD-CD-6G1F split as ≥93% OBC and ≥94% DC/DC.

All six series in this range are air-cooled. If your enclosure cannot move enough air, the honest answer is a different thermal design rather than a bigger fan — tell us the ambient and the duty cycle and we will say so.

When a 2-in-1 is the wrong choice

Two cases where splitting the functions is better:

  1. You need high-voltage distribution as well. If the vehicle also needs contactors, fusing and pre-charge for a high-voltage bus, the OBC + DC/DC + PDU 3-in-1 range folds distribution into the same housing instead of adding a third box.

  2. Charging and auxiliary power have very different duty cycles. On a machine that charges overnight but runs its auxiliary load all day, a dedicated converter may be easier to service than a shared housing. We build standalone OBCs and DC/DC converters for exactly that case.

Where a 2-in-1 module fits

Not defined by vehicle type. Three conditions decide it:

  • 48–320 V pack — the charger's output window must span your pack from empty to full

  • A 12–16 V auxiliary bus — lights, controllers, BMS, fans

  • One bay, not two — if there is room for separate units, buying separately is often cheaper

Body shape, duty cycle and market change the connector and the CAN map, not whether the architecture works.

Common programmes

2W / 3W and e-motorcycles
2W / 3W and e-motorcycles
A 1.5–3.3 kW charger and the 12 V rail in one housing — the space a two-wheeler does not have.
Read the guide →
Light commercial and last-mile vans
Light commercial and last-mile vans
Refrigeration, lift gates and telematics keep drawing auxiliary power while the pack charges.
Read the guide →
Off-road ATV and UTV
Off-road ATV and UTV
72–96 V packs, wash-down and continuous vibration — the sealed 2-in-1 build is specified for this duty.
Read the guide →
Engineering, agricultural and specialty vehicles
Engineering, agricultural and specialty vehicles
Short break windows and a real auxiliary load, on 48–96 V platforms.
Read the guide →
Electric boats and marine
Electric boats and marine
One housing keeps the high-voltage run short inside a wet compartment.
Read the guide →
Autonomous delivery robots
Autonomous delivery robots
Charging triggered at a docking point, with the auxiliary rail for controllers and sensors.
Read the guide →

Also in series: RVs and campers · Golf carts and LSVs · Forklifts and AGVs · Airport ground support · Sanitation · Agricultural tractors · Autonomous delivery — and vehicles not listed here.

Send the five numbers and we will say whether one of the six series fits, or whether the programme needs a separate unit.

Frequently asked questions

What is the difference between a 2-in-1 and a 3-in-1 on-board power module?

A 2-in-1 combines an on-board charger and a DC/DC converter. A 3-in-1 adds a power distribution unit, so high-voltage fusing, contactor control and pre-charge live in the same housing as well. Choose 2-in-1 when the vehicle already has a distribution box; choose 3-in-1 when the housing count is the constraint.

Can the DC/DC converter supply auxiliary loads while the battery is charging?

Yes — that is the main reason to integrate the two functions. Both operate from the same high-voltage bus, so auxiliary systems keep running during a charge session, which matters for vehicles that must stay powered on the charger: refrigerated vans, work platforms and machines with an active telematics unit.

Do I need liquid cooling for a 6.6 kW on-board charger?

Not automatically. The 6.6 kW series in this range is air-cooled, and air is usually sufficient when the module has its own airflow path and the ambient stays within the specified range. Liquid cooling becomes the better choice when the module sits in a sealed compartment or when ambient is high and the duty cycle is continuous.

What does the 6.6 kW rating mean on a 110 V supply?

It means 3300 W. The 6.6 kW figure applies to a 220–240 Vac input; on 110 Vac the same module delivers half the power. If your target market is 110 V only, size the vehicle's charge time from 3.3 kW.

How do I get a quote for a specific platform?

Send four things: nominal and maximum pack voltage, pack capacity in kWh or Ah, the continuous auxiliary load in watts, and the ambient temperature at the mounting position. With those we can name a model, state the charge time it delivers and flag whether the thermal path is realistic — usually within one working day.

Next step

Tell us the platform voltage and the auxiliary budget and we will shortlist the model that fits, or say plainly if none of the six does. Send your requirement or email nancy@tici-energy.com.