Two power levels, charger only. If the vehicle also needs an auxiliary rail, the 2-in-1 series does both in one housing — the comparison is further down.
Quick answer: a standalone OBC does one job — it converts AC into DC to charge the traction pack, and it does nothing else. That makes it the right choice when the vehicle already has a DC/DC converter, when the two functions are sourced or serviced separately, or when a fault in one should not disable the other. It is the wrong choice when bay volume is the constraint: two housings, two brackets and two harness runs cost more and fit worse than one 2-in-1.
Almost every vehicle needs both charging and an auxiliary rail, so "why not a 2-in-1" is a fair question. Four situations answer it:
Where the 2-in-1 wins is the opposite case: one bay, one bracket, one high-voltage run, and a vehicle where the auxiliary load is small but real. That is most light commercial and specialty EV programmes, which is why the 2-in-1 range is larger.
| Parameter | PO-AA-3D-72 | PO-AA-3D-96 |
|---|---|---|
| Battery platform | 72 V DC | 96 V DC |
| AC input | 90–264 Vac | 90–264 Vac |
| Output voltage | 50–100 V DC | 64–128 V DC |
| Output current | 0–40 A | 0–32 A |
| Output power | 3300 W @ 220 Vac 1650 W @ 110 Vac | 3300 W @ 220 Vac 1650 W @ 110 Vac |
| Efficiency | ≥93% | ≥93% |
| Cooling | Air | Air |
| Weight | 4.3 kg | 4.3 kg |
| Parameter | PO-AB-6G-96 | PO-AB-6G-320 |
|---|---|---|
| Battery platform | 96 V DC | 320 V DC |
| AC input | 90–264 Vac | 90–264 Vac |
| Output voltage | 64–128 V DC | 200–450 V DC |
| Output current | 0–60 A | 0–20 A |
| Rated power | 6.6 kW @ 220 Vac | 6.6 kW @ 220 Vac |
| Efficiency | ≥93% | ≥93% |
| Cooling | Air | Air |
| Weight | 6.5 kg | 6.5 kg |
Every model in both tables runs from 90–265 Vac, and every one delivers half its rated power on a 110 V supply. That single fact decides more installations than any other: a 3.3 kW unit is a 1.65 kW unit on a 110 V site, and a 6.6 kW unit is a 3.3 kW unit. Size the charge window from the supply that exists, not the one on the nameplate.
Divide the pack energy by the charger power the site can actually deliver, and treat the result as a floor rather than a promise. Three effects push real time beyond it:
A worked example: a 72 V, 100 Ah pack holds about 7.2 kWh. On a 3.3 kW charger at 220 V, the theoretical minimum is about 2.2 h; plan for 2.6–2.8 h. The same pack on a 110 V site with the same charger takes roughly twice as long, because the unit delivers 1.65 kW.
All four models are air-cooled, which suits an open bay and keeps the installation simple — no coolant circuit, no pump, no hose routing. It stops being the right answer in three cases:
| Situation | What to do |
|---|---|
| Sealed compartment, or mounted against the pack | Move to a liquid-cooled series, or redesign the bay for airflow |
| Ambient above roughly 45 °C for sustained periods | Expect derating; size for the worst week of the year |
| Washdown or de-icing fluid reaching the bay | Sealing and mounting orientation matter first — confirm the IP rating per model |
A charger that derates in summer is working as designed, but the customer experiences it as a charger that "sometimes charges slowly". Decide this from the bay, not from the datasheet.
| Standalone OBC | 2-in-1 (OBC + DC/DC) | |
|---|---|---|
| Housing count | One, plus a separate converter | One |
| Auxiliary rail | Not supplied — needs a separate converter | Integrated, 500 W–3 kW depending on series |
| Bay volume | Larger total footprint | Smaller, one bracket |
| Fault isolation | A converter fault leaves charging intact | One internal fault disables both |
| Service | Swap the failed unit on its own | Whole module out |
| Best fit | Existing converter, or separate service | Bay volume is the binding constraint |
If the vehicle is new and the bay is tight, a 2-in-1 is almost always the better default. Reach for a standalone charger when you have a specific reason — not because it is simpler to quote.
Not defined by vehicle type. Four conditions favour it:
Common programmes




Also in series: golf carts and LSVs · electric boats and marine — and vehicles not listed here.
Yes, unless the vehicle derives its low-voltage rail some other way. The standalone series supplies charging only — there is no auxiliary output. If you need both from one housing, the 2-in-1 series does it with a 500 W to 3 kW auxiliary rail depending on model.
Because the input current is limited. A 3.3 kW output at 110 V would draw more current than the module and the typical circuit allow, so the unit delivers 1.65 kW instead. This is normal for the whole range, not a fault — plan the charge window from the supply that exists at the site.
Orientation matters more than the datasheet suggests, particularly where washdown or condensation is present. Connector orientation and drain direction decide whether water reaches the electronics. Ask for the recommended mounting envelope for the specific model rather than assuming upright.
Power level and platform coverage: PO-AA-3D is 3.3 kW for 72 V and 96 V packs at 4.3 kg; PO-AB-6G is 6.6 kW for 96 V and 320 V packs at 6.5 kg. Both are air-cooled, both take 90–264 Vac, both deliver ≥93% efficiency.
Send the pack voltage range, the charge power target, the supply voltage at each site, and whether the vehicle already has an auxiliary converter. With those we can name a model and give you a realistic charge time rather than a nameplate figure.
Tell us the pack voltage, the supply at each site and whether an auxiliary rail already exists. We will say whether a standalone charger is the right call — or whether a 2-in-1 would fit the bay better and cost less overall.