Four power levels from 500 W to 10 kW. Three are auxiliary supplies; the 10 kW unit is a charging stage. The distinction matters for how you size them.
Quick answer: a DC/DC converter turns the traction pack voltage into a regulated low-voltage rail — usually 13.8 V or 14 V — for controllers, lighting, pumps, fans and telematics. The range here covers 500 W to 10 kW, but they are not one product line scaled up: the first three are auxiliary supplies sized from a load list, and the 10 kW unit is a charging stage sized from a charge window.
The catalogue groups these together because they all convert DC to DC. In use they divide cleanly:
| Auxiliary converters (500 W – 1.2 kW) | Charging module (10 kW) | |
|---|---|---|
| What it does | Supplies the low-voltage rail while the vehicle runs | Charges the traction pack from a DC source |
| Rated by | The continuous auxiliary load in watts | The charge power the pack can accept |
| Load characteristic | Steady with start-up peaks | Regulated current into a battery, with a taper at the end |
| If undersized | Lights dim, controllers reset, BMS drops out | The charge simply takes longer |
| Typical platform | 48–200 V in, 13.8–14 V out | 96 V platform, high-voltage output |
Sizing one as if it were the other is the usual mistake. An auxiliary converter sized from a charge-power figure will be enormous and wasteful; a charging module sized from a load list will not charge anything.
Add the continuous low-voltage draw at worst case, then add headroom for what starts. Four groups, and buyers usually forget the fourth:
The rated figure covers continuous draw. Peak figures — 600 W on the 500 W unit, 1200 W on the 1 kW series — are short windows for motor and compressor start-up. Do not plan to run at peak continuously; the units are rated the way they are for a reason.
| Parameter | PD-BA-0F-96Y | PD-BI-1A series | Automotive unit |
|---|---|---|---|
| Rated power | 500 W | 1000 W | 1.2 kW |
| Peak power | 600 W (6 min) | 1200 W (model dependent) | — |
| Input voltage | 64–133 V DC | 48 / 72 / 96 V DC nominal | 80–200 V DC |
| Output voltage | 9–16 V DC | 14 ±0.2 V DC | 13.8 ±0.2 V DC |
| Rated output current | 36 A | 72 A | — |
| Peak current | 46 A | — | — |
| Efficiency | ≥93% | ≥94% | — |
| Cooling | Natural | Natural (fanless) | Air or water |
| Weight | 1.35 kg | — | — |
| Protection | Confirm per model | Confirm per model | IP66–IP67 |
| Communication | CAN bus | CAN bus | CAN + UDS diagnostics |
| Parameter | PD-BH-AA-300J |
|---|---|
| Rated power | 10 kW |
| Function | DC/DC charging stage, not an auxiliary supply |
| Platform | 96 V EV battery platform |
| Communication | CAN bus |
| Protection | Over-voltage, over-current, over-temperature |
Blank cells above are deliberate: those figures are not published for every model, and guessing them is worse than asking. Request the datasheet for the exact part number before the drawing pack goes out — particularly weight, which decides whether the bracket you have in mind will work.
Three options across the range, and the choice follows the bay as much as the power:
| Method | Where it fits | Watch out for |
|---|---|---|
| Natural (fanless) — 500 W and 1 kW series | Sealed enclosures, dusty environments, anywhere a fan bearing is a maintenance item | Needs surface area, not airflow. Mounting against a flat plate helps; hanging in free air does not |
| Air — automotive unit option | Open bays with a real airflow path | A fan in a sealed box is still a sealed box. Clearance is not airflow |
| Water — automotive unit option | Sealed compartments, or continuous high load | Adds a coolant circuit and a pump. Not worth it below about 1 kW |
The fanless series is the interesting one for retrofit work: no moving parts, so no bearing to fail and nothing to maintain. The constraint it imposes is thermal mounting surface, which is easy to satisfy in a design review and easy to get wrong in a prototype.
Not defined by vehicle type. The auxiliary series and the charging module answer different questions:
Common programmes




Also in series: golf carts and LSVs · electric boats and marine — and vehicles not listed here.
No. A charger takes AC and charges the pack; a converter takes the pack voltage down to a low-voltage rail. They are often combined in one housing as a 2-in-1, which is why the two appear side by side in a catalogue — but they do opposite jobs.
It is a charging stage, not an auxiliary supply. Its output is sized for charging a 96 V platform, not for a 13.8 V rail. If you need both, they are separate functions and usually separate units.
Natural cooling moves heat through the housing into whatever it is mounted on. A unit bolted to a flat metal plate sheds heat well; the same unit hanging in free air sheds very little, because the only path is still air. Specify the mounting surface as part of the thermal design, not as an afterthought.
IP66 resists powerful water jets; IP67 survives short-term immersion. The automotive unit is quoted across that range depending on configuration, so confirm which applies to your part number and mounting position — washdown and immersion are different requirements.
Add the continuous low-voltage draw at worst case — lighting, body and comfort, control and telematics, plus anything the customer may add — then add headroom for motor and compressor start-ups. Size the continuous total against the rated figure and the start-up peaks against the peak rating, not the other way round.
Send the pack voltage range, the continuous auxiliary load in watts and the peak start-up draw. We will name the model that covers it with margin — or tell you that the load list needs a second look before anything is specified.