Views: 0 Author: ECHELON Publish Time: 2026-10-30 Origin: Site
Marine is the harshest environment in this product category: salt, constant humidity, and a charging location — a marina pontoon — where the electrical supply is shared, variable and often poorly maintained.
Four constraints come up repeatedly:
1. Corrosion. Salt air attacks every exposed connection. A connector that lasts years inland can fail in a single season on a saltwater pontoon.
2. Shore power variability. Marina supply quality varies by marina and by time of day, and the charger has to accept what it is given.
3. Isolation and safety. Water plus high voltage demands that grounding and isolation are correct rather than merely adequate.
4. Long dwell times. A boat may charge for eight to twelve hours with nobody present, so unattended operation is the normal case rather than the exception.
For marine we are conservative on both ingress protection and on what we will claim. We do not offer a marine-specific classification beyond our standard CE-marked configurations. Where a customer needs classification-society approval, we say so up front instead of implying it exists.
On-board charging, sealed, moderate power: 3 kW OBC + 1 kW DC/DC 2-in-1 (OD-CE-3D1A series).
Higher power for larger packs: 6.6 kW OBC + 1.5 kW DC/DC 2-in-1 (OD-CD-6G1F series).
Quiet sealed operation with no exposed airflow: liquid-cooled configurations.
Why we do not oversell marine. This is the segment where over-claiming is most costly, because a failed charger on open water is a safety event rather than a warranty claim. We prefer to define the application limits clearly and let the customer decide whether the product fits.
Why mounting matters more at sea than inland. A sealed module in a protected compartment and the same module on an exposed bracket are not the same installation. We would rather recommend a protected compartment and a defined exposure limit than promise a rating the installation cannot support.
Why unattended charging drives the specification. With eight to twelve hour sessions and nobody aboard, protection behaviour matters more than charge speed. Over-temperature, input under-voltage and isolation behaviour all have to be correct without an operator watching.
A lake tour-boat operator needed to replace a failed imported charger inside a fixed deadline before high season. We supplied a standard CE-marked on-board unit, sealed for splash exposure and mounted in a protected compartment rather than an exposed position. The operator accepted a defined limit on saltwater exposure in exchange for the delivery date, which was the honest trade rather than an unverified marine claim.
3 kW OBC + 1 kW DC/DC 2-in-1
Sealed on-board charging for protected compartments.
Power: 3 kW + 1 kW
Voltage: 72 / 96 / 320 V
Models: OD-CE-3D1A-72, -96, -320
Cooling: Air
6.6 kW OBC + 1.5 kW DC/DC 2-in-1
Higher power for larger marine packs.
Power: 6.6 kW + 1.5 kW
Voltage: 72 / 96 / 320 V
Models: OD-CD-6G1F-72, -96, -320
Cooling: Air
11 kW Bidirectional OBC + 3 kW DC/DC
Liquid-cooled, no exposed airflow.
Power: 11 kW + 3 kW
Voltage: 360 V
Models: OD-CN-BA3A-360Y
Cooling: Liquid
Tell us whether the boat runs freshwater or saltwater, whether charging happens alongside or on open water, and whether any classification approval is required. We will tell you plainly whether our standard range fits the application.