Choosing the right onboard charger is only the beginning. Successful vehicle integration depends on AC input conditions, battery compatibility, communication, thermal management, and system-level validation.

An on-board charger (OBC) may look like a straightforward component on a vehicle specification sheet. But once integration begins, OEM engineering teams often discover that matching the charging power and battery voltage is only part of the work.

Consider a 6.6kW OBC selected for an electric commercial vehicle. The rated power meets the project requirement, and the DC output range appears compatible with the battery.

But several questions remain:

  • Can the available AC supply deliver enough current?

  • How will the OBC communicate with the battery management system (BMS)?

  • What happens if charging communication is interrupted?

  • Can the installation provide sufficient cooling under actual operating conditions?

  • What must be validated before the vehicle enters production?

These questions are especially relevant for electric utility vehicles, delivery vehicles, agricultural equipment, ground support equipment (GSE), and other specialty EVs.

This guide outlines seven practical questions OEM teams should answer before integrating an AC onboard charger into a new vehicle platform.

1. What AC Power Is Actually Available to the Vehicle?

One of the first things to confirm is not the OBC's rated output power, but the AC supply available at the intended charging location.

A charger rated at 6.6kW does not necessarily deliver 6.6kW under every input condition.

For example, consider a single-phase 6.6kW charger operating from a 220V AC supply.

Ignoring conversion losses and power factor, the approximate input current would be:

6,600W ÷ 220V = 30A

In practice, the actual input current depends on charger efficiency, power factor, and operating conditions.

If the available charging circuit cannot support the required current, charging power may need to be limited.

This matters for vehicles operating in different environments:

  • Electric delivery vehicles: Charging may take place overnight at a depot with shared electrical capacity.

  • Utility vehicles: Charging infrastructure may vary between customer sites.

  • Agricultural EVs: The available power supply may be limited or located far from dedicated charging facilities.

  • Airport ground support equipment: Multiple vehicles may need to charge within the same operating window.

What should OEMs confirm?

Before selecting the OBC, clarify the AC input voltage, frequency, available current, charging interface, and expected charging schedule.

The goal is to match the charger to the infrastructure the vehicle will actually use—not just the maximum power listed in a datasheet.

2. Does the OBC Cover the Full Battery Charging Voltage Range?

A battery's nominal voltage does not describe its complete operating range.

For example, a vehicle may use a nominal 320V battery system, but its charging voltage requirements can extend considerably above and below that nominal value.

The OBC must support the battery's required charging voltage range and deliver appropriate current throughout the intended charging profile.

This is particularly important when OEMs use different battery chemistries, pack configurations, or battery suppliers across vehicle variants.

Two vehicles described as using the same nominal battery voltage may still require different charging parameters.

What should OEMs confirm?

Provide the OBC supplier with:

  • Battery nominal voltage

  • Minimum and maximum charging voltage

  • Maximum permissible charging current

  • Battery chemistry and charging strategy

  • BMS-controlled charging limits

For example, Echelon's published 3.3kW standalone OBC series includes versions for 72V, 96V, and 320V battery platforms, with different DC output ranges for each version.

The correct model should be selected based on the full battery charging requirements rather than nominal voltage alone.

3. Who Handles EVSE Communication and Charging Control?

An onboard charger does not operate independently of the vehicle's charging interface.

During AC charging, the vehicle must coordinate with the external electric vehicle supply equipment (EVSE) and determine the charging conditions permitted by the system.

Depending on the charging standard and vehicle architecture, communication and control functions may be distributed among the charging inlet electronics, vehicle controller, BMS, and OBC.

For example, an AC charging interface may communicate available current through control-pilot signaling, while internal vehicle communication provides charging commands and battery limits to the OBC.

The exact responsibilities depend on the system design.

This distinction is important because supporting CAN communication does not automatically mean that an OBC independently supports every regional AC charging interface or protocol.

What should OEMs confirm?

Before integration, define:

  1. Which component processes the external charging interface signals?

  2. Which controller authorizes charging to begin?

  3. How does the OBC receive its charging voltage and current commands?

  4. What happens when the external supply limits available current?

  5. How is charging stopped during a fault or communication interruption?

Clear responsibility for each function can prevent interface misunderstandings during prototype development.

4. How Should the OBC, BMS and Vehicle Controller Coordinate?

The OBC, battery management system, and vehicle control unit each have different responsibilities.

The BMS monitors battery conditions and determines permissible charging limits according to the battery's design and operating state.

The OBC regulates its output according to the applicable commands and limits.

The vehicle controller may coordinate charging authorization, system states, diagnostics, and other vehicle functions.

In many EV architectures, CAN communication connects these systems.

However, successful CAN integration requires more than matching the physical communication interface.

OEM teams should also agree on message definitions, update rates, control logic, fault handling, and software version management.

Questions worth reviewing

Charging enable and stop logic

What conditions must be satisfied before charging begins? Which system can request an immediate stop?

Current and voltage commands

How are permissible charging limits transmitted, and what happens if the requested values change during charging?

Communication timeout

What should the charger do if expected CAN messages stop arriving?

Fault reporting

Which fault codes and operating states must be available to the BMS or vehicle controller?

Software compatibility

How are communication changes managed between prototype, pilot production, and mass production?

For OEM projects, confirming these details early can reduce unnecessary troubleshooting during vehicle-level testing.

5. What Cooling and Installation Conditions Must Be Verified?

An OBC's electrical specifications are only part of its integration requirements.

The installation environment can affect charging performance, thermal behavior, and long-term reliability.

For an air-cooled OBC, airflow availability is particularly important.

A charger may perform as expected during bench testing but encounter different thermal conditions when installed inside a restricted vehicle compartment.

Potential concerns include:

  • Insufficient ventilation around the enclosure

  • Restricted or blocked cooling airflow

  • Heat from nearby vehicle components

  • High ambient operating temperatures

  • Dust, mud, and moisture exposure

  • Vibration and mechanical stress

For liquid-cooled designs, OEMs must also evaluate coolant flow, temperature, pressure, and cooling-system interfaces.

Does IP67 mean the charger is suitable for every outdoor application?

No.

An IP67 rating addresses defined dust-ingress and temporary water-immersion test conditions. It does not automatically establish resistance to high-pressure washing, vibration, thermal cycling, or every environmental condition encountered during vehicle operation.

For construction equipment, agricultural EVs, and other outdoor vehicles, mounting position and connector exposure deserve particular attention.

What should OEMs confirm?

Review the installation location, mounting orientation, available airflow or coolant conditions, connector direction, operating temperature, and vehicle-specific environmental validation requirements.

The installation should be assessed as part of the complete vehicle system.

6. When Does Bidirectional Charging Make Sense?

Traditional onboard charging transfers energy from an AC source to the vehicle battery.

A bidirectional OBC is designed to support controlled energy conversion in both directions.

This can create additional functions for certain vehicle applications.

Vehicle-to-Load (V2L)

V2L enables compatible vehicles to supply electrical power to external loads.

For utility vehicles and specialized equipment, this may be useful where access to external electricity is limited.

Vehicle-to-Vehicle (V2V)

V2V energy transfer may support certain vehicle-to-vehicle power-sharing applications, depending on the system architecture.

Vehicle-to-Grid (V2G)

V2G enables compatible vehicles to export energy to the electricity grid.

However, this requires appropriate grid-interface hardware, communication, protection, control, and compliance with applicable requirements.

A bidirectional power converter alone is not sufficient to establish V2G functionality.

What should OEMs consider?

Before specifying a bidirectional OBC, determine whether the vehicle actually needs external energy output.

Questions include:

  • What external load or energy-transfer function is required?

  • What output voltage and power are needed?

  • How will discharge be enabled and controlled?

  • What battery limits must be enforced during discharge?

  • Which connectors, protection functions, and communication interfaces are required?

  • What additional system-level validation is necessary?

Bidirectional capability can add value to the right application, but it should be specified according to a defined vehicle requirement rather than included automatically.

7. What Should Be Validated Before Prototype Approval and Production?

A successful bench test is an important milestone, but it does not necessarily demonstrate that an OBC is ready for every vehicle application.

Before moving from prototype evaluation toward production, OEMs and suppliers should agree on the validation scope.

This may include the following areas.

Electrical performance

Verify charging operation across the required AC input and battery voltage ranges.

Confirm output regulation, current limits, and expected charging behavior under relevant operating conditions.

Communication and control

Check CAN message compatibility, charging commands, timeout behavior, fault reporting, and recovery logic.

Thermal performance

Evaluate the OBC under relevant temperature, cooling, and power conditions, including appropriate abnormal operating scenarios.

Electrical protection

Confirm the required response to overvoltage, undervoltage, overcurrent, short circuit, and other defined faults.

Mechanical and environmental performance

Assess mounting, vibration, sealing, connectors, and environmental exposure according to the intended vehicle application.

Production configuration control

Confirm hardware and firmware versions, connector configurations, labeling, test requirements, and approved technical documentation.

For repeat-production vehicle programs, these details help ensure that production units match the configuration evaluated during development.

What Should OEMs Confirm Before Discussing Integration with a Supplier?

The following checklist can help engineering and purchasing teams prepare for discussions with an OBC manufacturer.

Requirement

Information to Confirm

Why It Matters

Vehicle application

Vehicle type and operating conditions

Defines the integration environment

Battery system

Nominal and full charging voltage range

Determines DC output compatibility

AC input

Voltage, frequency, available current

Determines practical charging capability

Charging power

Required power and charging time

Supports power-rating selection

BMS interface

CAN messages and charging commands

Enables coordinated charging control

Charging interface

EVSE interface and control responsibilities

Clarifies system compatibility

Cooling

Air or liquid cooling requirements

Supports thermal performance

Installation

Dimensions, mounting and connectors

Determines mechanical compatibility

Protection

Electrical and environmental requirements

Defines validation scope

Project plan

Sample quantity, validation schedule and SOP

Supports development planning

The more clearly these requirements are defined, the easier it becomes to determine whether an existing OBC can be used or whether customization is needed.

Standalone OBC or Integrated Power Unit?

After confirming the charging requirements, OEM teams should also consider how the OBC fits into the broader vehicle power architecture.

Some projects use a standalone OBC.

Others combine the OBC with a DC-DC converter or power distribution unit.

Common configurations include:

  • Standalone OBC: Dedicated AC-to-DC battery charging function.

  • OBC + DC-DC 2-in-1: Battery charging and auxiliary low-voltage power conversion in one assembly.

  • OBC + DC-DC + PDU 3-in-1: Charging, auxiliary power conversion, and high-voltage power distribution within an integrated unit.

Integration may simplify packaging and external connections, while standalone components can provide greater flexibility in component placement and replacement.

The best architecture depends on the vehicle's electrical requirements, available space, service strategy, and project priorities.

For a more detailed comparison, see our related guide: 3-in-1 vs. Standalone OBC / DC-DC / PDU: How to Choose for Commercial and Specialty EVs.

3-3.jpg

Standalone OBC 3.3kW — Air-cooled 3.3kW standalone onboard charger with CAN bus; models cover 72V, 96V, and 320V battery platforms.

6.6KW+1.5KW 2in1-4.jpg

6.6kW OBC + 1.5kW DC-DC 2-in-1 — 6.6kW onboard charger with 1.5kW DC-DC converter in one integrated module for 72V, 96V, and 320V platforms.

3.3KW+1KW+PDU 1.jpg

3.3kW OBC + 1kW DC-DC + PDU 3-in-1 — 3.3kW onboard charger, 1kW DC-DC converter, and power distribution in one integrated unit.

Frequently Asked Questions

Can a 6.6kW OBC always deliver 6.6kW from a single-phase AC supply?

No. Actual charging power depends on the available input voltage and current, charger efficiency, operating limits, and the battery's permissible charging conditions.

Can one OBC model work with different battery voltage platforms?

Some OBC product families offer multiple voltage versions. However, each selected model must cover the battery's required charging voltage and current range.

Is CAN communication enough to integrate an OBC with a vehicle?

No. CAN hardware compatibility is only the starting point. Message definitions, charging commands, timeout behavior, fault handling, and software compatibility must also be confirmed.

Does every bidirectional OBC support V2L, V2V and V2G?

No. The supported functions depend on the converter design and the complete vehicle energy-transfer system.

What information should an OEM provide before requesting an OBC sample?

At minimum, provide the battery charging voltage range, AC input conditions, required charging power, communication requirements, cooling and installation conditions, and intended vehicle application.

Discuss Your OBC Integration Requirements with Echelon Energy

Selecting an onboard charger is not only about choosing a power rating. It is about ensuring that the charger can operate correctly within the complete vehicle system.

Echelon Energy Technology (Hangzhou) Co., Ltd. develops and manufactures onboard chargers, DC-DC converters, and integrated power solutions for commercial and specialty electric vehicle applications.

Our product portfolio includes standalone 3.3kW and 6.6kW OBC configurations, OBC + DC-DC 2-in-1 units, OBC + DC-DC + PDU 3-in-1 systems, and selected bidirectional integrated solutions.

For OEM projects, electrical requirements, communication interfaces, connectors, and integration needs can be reviewed to determine whether an existing configuration or a customized solution is appropriate.

Developing a new electric vehicle platform?

Share your vehicle application, battery voltage range, AC input, charging power, and communication requirements with our team.

We can help review the available product configurations and discuss the next steps for technical evaluation.

Next Step

Send the Echelon team the vehicle application, battery charging voltage range, AC input conditions, required charging power, and communication requirements, and ask which OBC configuration fits the integration requirements.

Contact Echelon directly: Email nancy@tici-energy.com · WhatsApp +86 18114665311.

Use the contact form on the contact page to start the discussion, and see how a custom programme is scoped on the OEM/ODM page.

Get in Touch

Quick Links

Support

Product Category

Contact Us

Tel: +86-181 14665311
Add: Room 301, 3rd Floor, Building 2, No.1 Luoyang Road, Renhe Sub-district, Yuhang District, Hangzhou
 
Copyright © 2026 Echelon Energy Technology(Hangzhou) Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy